3com S7906E Guide De Référence
1-16
display poe-power alarm
Syntax
display poe-power alarm
View
Any view
Default Level
1: Monitor level
Parameters
None
Description
Use the display poe-power alarm command to display the alarm information of the PoE power.
Examples
# Display the alarm information of the PoE power.
<Sysname> display poe-power alarm
PSU Number : 3
PSU 1 State : Normal
PSU 2 State : Disconnect
PSU 3 State : Over Voltage
Over Temperature
Table 1-11 display poe-power alarm command output description
Field
Description
PSU Number
Number of PSUs
PSU x State
PSU state:
z
Normal: The PSU is normal.
z
Disconnect: The PSU is disconnected.
z
Input Error: An input error occurs to the PSU.
z
Output Error: An output error occurs to the PSU.
z
Over Voltage: An over-voltage occurs to the PSU.
z
Over Temperature: An over-temperature occurs to the
PSU.
PSU.
z
Fan Error: A fault occurs to the fan of the PSU.
z
Shut Down: The PSU is shut down.
z
Current Restricted: The current of the PSU is restricted.
display poe-power dc-output state
Syntax
display poe-power dc-output state