3com S7906E Guide De Référence

Page de 2327
 
1-2 
<Sysname> system-view 
[Sysname] port-group manual 1 
[Sysname-port-group-manual-1] group-member GigabitEthernet 2/0/1 to gigabitethernet 2/0/6 
[Sysname-port-group-manual-1] stp disable 
[Sysname-port-group-manual-1] bpdu-tunnel dot1q stp 
bpdu-tunnel tunnel-dmac 
Syntax 
bpdu-tunnel tunnel-dmac mac-address 
undo bpdu-tunnel tunnel-dmac 
View 
System view 
Default Level 
2: System level 
Parameters 
mac-address: Destination multicast MAC address for BPDU tunnel frames, in the format of H-H-H. The 
allowed values are 0100-0CCD-CDD0, 0100-0CCD-CDD1, 0100-0CCD-CDD2, and 010F-E200-0003. 
Description 
Use the bpdu-tunnel tunnel-dmac command to configure the destination multicast MAC address for 
BPDU tunnel frames. 
Use the undo bpdu-tunnel tunnel-dmac command to restore the default value. 
By default, the destination multicast MAC address for BPDU tunnel frames is 0x010F-E200-0003. 
Examples 
# Set the destination multicast MAC address for BPDU tunnel frames to 0100-0CCD-CDD0. 
<Sysname> system-view 
[Sysname] bpdu-tunnel tunnel-dmac 0100-0ccd-cdd0