3com S7906E Guide De Référence

Page de 2327
 
3-14 
The system generates an error frame seconds summary alarm when the number of error frame 
seconds (in an error frame second, at least one error frame occurs) in a specific time period (for 
example, 1 minute) exceeds the corresponding predefined threshold. 
Related commands: alarm oam error-frame-seconds-summary enable.  
 
 
The commands here take effect only for OAM 2.0 and above.  
 
Examples 
# Set the window size and alarm threshold for error frame seconds summary to 800 and 2 on ONU 
1/0/1:1.  
<Sysname> system-view 
[Sysname] interface onu 1/0/1:1 
[Sysname-Onu1/0/1:1] alarm oam error-frame-seconds-summary window 800 threshold 2 
alarm oam error-frame-seconds-summary enable 
Syntax 
alarm oam error-frame-seconds-summary enable 
undo alarm oam error-frame-seconds-summary enable 
View 
OLT port view, ONU port view, FTTH view 
Default Level 
2: System level 
Parameters 
None 
Description 
Use the alarm oam error-frame-seconds-summary enable command to enable the error frame 
seconds summary alarm. 
Use the undo alarm oam error-frame-seconds-summary enable command to disable the error 
frame seconds summary alarm. 
By default, the error frame seconds summary alarm is enabled.