3com S7906E Guide De Référence

Page de 2327
 
1-15 
View 
Ethernet interface view 
Default Level 
2: System level 
Parameters 
None 
Description 
Use the flow-control command to enable flow control on an Ethernet interface. 
Use the undo flow-control command to disable flow control on an Ethernet interface. 
By default, flow control on an Ethernet interface is disabled. 
 
 
The flow control function takes effect on the local Ethernet interface only when it is enabled on both the 
local and peer devices. 
 
Examples 
# Enable flow control on interface Ethernet 2/0/1. 
<Sysname> system-view 
[Sysname] interface ethernet 2/0/1 
[Sysname-Ethernet2/0/1] flow-control 
flow-interval 
Syntax 
flow-interval interval 
undo flow-interval 
View 
Layer 2 Ethernet interface view 
Default Level 
2: System level 
Parameters 
interval: Time interval at which interface statistics are collected, in the range of 5 to 300 seconds, a 
multiple of 5. The default value is 300 seconds. 
Description 
Use the flow-interval command to configure the time interval for collecting interface statistics.