Maintenance and Cleaning
When the projection lamp of the projector 
reaches its end of life, the Lamp replacement 
icon appears on the screen and LAMP 
REPLACE indicator lights yellow. Replace the 
lamp with a new one promptly. The timing when 
the LAMP REPLACE indicator should light is 
depending on the lamp mode.
Follow these steps to replace the 
lamp.
For continued safety, replace with a lamp of the 
same type. Do not drop a lamp or touch a glass 
bulb! The glass can shatter and may cause 
injury.
Allow a projector to cool for at least one hour 
before you open the Lamp Cover. The inside 
of the projector can become very hot.
CAUTION
Unplug the AC power cord. Let the projector 
cool for at least one hour.
Loosen the three (3) screws that secure the 
lamp. Lift the lamp out of the projector by 
using the handles.
1
3
Replace the lamp with a new one and 
secure the three (3) screws. Make sure that 
the lamp is set properly. Close the lamp 
cover and secure the screw.
4
Loosen the screw and open the lamp cover.
2
Connect the AC power cord to the projector 
and turn on the projector.
5
Lamp Replacement
CAUTION
Top Control
LAMP 
REPLACE 
indicator
lights yellow
Screw
Handles
Screw
Lamp Cover
Screw
Screw
CAUTION
When replacing the lamp because it has stopped illuminating, there is a possibility that the lamp 
may be broken.
If replacing the lamp of a projector which has been installed on the ceiling, you should always 
assume that the lamp is broken, and you should stand to the side of the lamp cover, not 
underneath it. Remove the lamp cover gently. Small pieces of glass may fall out when the lamp 
cover is opened. If pieces of glass get into your eyes or mouth, seek medical advice immediately.
Note:
     • The image will be displayed for about 10 seconds.
     •  The Lamp replacement icon will not appear when the Display function is set to 
Off (p.53), during Freeze (p.28), 
or 
Blank (p.29).
Lamp replacement icon
OK
POWER
AUTO SET
MENU
LAMP REPLACE
WARNING
VOL
VOL
Reset the lamp counter.
See "Lamp Counter" on page 62.
6
Lamp