Cisco Cisco Unified MeetingPlace Audio Server Manuel De Maintenance
5-16
Cisco MeetingPlace Audio Server 5.2 Customer Engineering Guide (for Cisco MeetingPlace 8112)
OL-
Chapter 5 Repairing and Maintaining the 8112 Server
Replacing the floppy drive
Figure 5-11 hwconfig Command
Step 5
Verify the output for the power supply units and their fans is like lines 9-12 in
.
Note
The floppy drive and CD-ROM drive do not show up in the “hwconfig” command output even
when they are installed and running.
when they are installed and running.
Replacing the floppy drive
This section describes how to replace a floppy drive.
Note
The floppy drive is housed in the back of the server. The floppy drive housing must be removed from the
server before replacing the actual floppy drive.
server before replacing the actual floppy drive.
meetingplace:tech$ hwconfig
Cabinet: Motorola CPX8216T
Bus architecture: CompactPCI
Processor card: CPV5370 S/N=5129443
Processor: Pentium III, Model 8, 700 MHz
Memory: 512MB
Temperature: 31C
Voltages: 3.32V, 5.02V, 12.06V
Power Supplies:
PS1: OK, fan is OK
PS2: OK, fan is OK
PS3: OK, fan is OK
SCSI Adapter: NCR 810
DISK 1: 36000MB (SEAGATE ST336704LW REV=0004)
DISK 2: 36000MB (SEAGATE ST336704LW REV=0004)
Solid State Disk: IMPERIAL "MG-35/400 ULTRA" S/N=0128 REV=B403
Battery: usage = 307 days, charge is OK
Ethernet: Intel 8225x PCI 10/100 (0001af03c05e)
Modem: Absent or unrecognized
Smart Blades:
Slot 16: NMS CG6000C S/N=20363257 REV=5894-B2 MSC0 PRC0
Slot 15: NMS CG6000C S/N=20363261 REV=5894-B2 MSC1 PRC1