Cisco Cisco Unified MeetingPlace Audio Server Maintenance Manual

Page of 349
5-16
Cisco MeetingPlace Audio Server 5.2 Customer Engineering Guide (for Cisco MeetingPlace 8112)
OL-
Chapter 5      Repairing and Maintaining the 8112 Server
  Replacing the floppy drive
Figure 5-11 hwconfig Command
Step 5
Verify the output for the power supply units and their fans is like lines 9-12 in 
.
Note
The floppy drive and CD-ROM drive do not show up in the “hwconfig” command output even 
when they are installed and running.
Replacing the floppy drive
This section describes how to replace a floppy drive.
Note
The floppy drive is housed in the back of the server. The floppy drive housing must be removed from the 
server before replacing the actual floppy drive.
meetingplace:tech$ hwconfig
Cabinet:                Motorola CPX8216T
Bus architecture:       CompactPCI
Processor card:         CPV5370 S/N=5129443
    Processor:          Pentium III, Model 8, 700 MHz
    Memory:             512MB
    Temperature:        31C
    Voltages:           3.32V, 5.02V, 12.06V
Power Supplies:
    PS1:                OK, fan is OK
    PS2:                OK, fan is OK
    PS3:                OK, fan is OK
SCSI Adapter:           NCR 810
    DISK 1:             36000MB (SEAGATE  ST336704LW       REV=0004)
    DISK 2:             36000MB (SEAGATE  ST336704LW       REV=0004)
    Solid State Disk:   IMPERIAL "MG-35/400 ULTRA" S/N=0128 REV=B403
                        Battery: usage = 307 days, charge is OK
Ethernet:               Intel 8225x PCI 10/100 (0001af03c05e)
Modem:                  Absent or unrecognized
Smart Blades:
    Slot 16:            NMS CG6000C S/N=20363257 REV=5894-B2 MSC0 PRC0
    Slot 15:            NMS CG6000C S/N=20363261 REV=5894-B2 MSC1 PRC1