Cisco Cisco IOS Software Release 12.2
21
Resolved Caveats—Release 12.2(10)DA
OL-3177-01B
Caveats
Resolved Caveats—Release 12.2(10)DA
The problems listed in
are fixed in Cisco IOS Release 12.2(10)DA.
Table 8
Caveats Resolved in Cisco IOS Release 12.2(10)DA
Caveat Number
Description
CSCdp00996
Periodically, the system generates a serial management bus cyclic redundancy
check (SMBCRC) error message such as this:
check (SMBCRC) error message such as this:
%NI2-5-LC_NOTICE:Slot[15] SMBCRC (1 days, 3 hours, 37 minutes,
6 seconds)
These messages are informational only and do not affect performance.
CSCdu04045
The entry for the atmSoftPVccRetryThreshold feature has an incorrect default
value of 0, rather than the default value of 1 that is shown in the ATM soft PVC
Management Information Base (MIB). A value of zero indicates that an infinite
number of call attempts are required to increment the atmSoftPvcCallFailures
object and thus disables alarms for the soft PVC.
value of 0, rather than the default value of 1 that is shown in the ATM soft PVC
Management Information Base (MIB). A value of zero indicates that an infinite
number of call attempts are required to increment the atmSoftPvcCallFailures
object and thus disables alarms for the soft PVC.
CSCdu40049
Adding and deleting a profile from different sessions (for example, in two Telnet
sessions, one user is adding while at the same time another is deleting the same
profile) has the potential of causing an unexpected system reload.
sessions, one user is adding while at the same time another is deleting the same
profile) has the potential of causing an unexpected system reload.
CSCdu42394
The ceAssetTag cannot be set for 8xDMT and SHDSL line cards.
CSCdv56813
Following a redundancy switchover, the standby card may reload twice before
reaching the STANDBY-READY state. Once the standby is in the
STANDBY-READY state it will not continue to reload.
reaching the STANDBY-READY state. Once the standby is in the
STANDBY-READY state it will not continue to reload.
CSCdv73591
Some VCs (PVCs/PVPs/Soft PVCs/Soft PVPs) are missing on reload even when
they are stored in the startup configuration. This problem occurs if you create VCs
by using internal CTT rows that do not appear in the show running-config
command but do appear in the show atm connection-traffic-table command.
they are stored in the startup configuration. This problem occurs if you create VCs
by using internal CTT rows that do not appear in the show running-config
command but do appear in the show atm connection-traffic-table command.
CSCdw53009
When you configure the ATUC-1-4DMT line card for loopback diagnostic, cells
are dropped by the interface.
are dropped by the interface.
CSCdw67176
The commands no tag-switching ip and tag-switching ip from the global
configuration mode remove the tag-switching atm vp-tunnel 13 vci-range
33-65535 line on the sub interfaces.
configuration mode remove the tag-switching atm vp-tunnel 13 vci-range
33-65535 line on the sub interfaces.
CSCdw73531
Not all IMA group/link alarms are shown in the event browser.
CSCdw87272
If you try to enable tag-switching ip, the following message appears:
%VP-tunnel
vpi is not free for Tag-switching
.
CSCdw91698
The NI-2 card does not support OAM F5 seg-loopback cells, in the fast path.
CSCdx16449
PNNI fails to establish a connection. The show atm controller atm 0/0 command
displays a status of C.
displays a status of C.
CSCdx19656
Unable to train with 3Com OCR-810. With the 4xDMT line card, the CPE
exhibited line errors and failures in training with Release 12.2(7)DA. Trellis
encoding is enabled in the DSL profile.
exhibited line errors and failures in training with Release 12.2(7)DA. Trellis
encoding is enabled in the DSL profile.
CSCdx34262
When you change the operation of the linecard from ATUC-1-DMT8 to
STUC-8-TCPAM, the indexes appear in the incorrect order.
STUC-8-TCPAM, the indexes appear in the incorrect order.
CSCdx43027
The system stops responding indefinitely after you provisioning or unprovision
slots.
slots.