Cisco Headend System Release 2.7 Mode D'Emploi

Page de 84
 
 
SDV System Communications Alarms 
4000308 Rev B 
11 
 
SDV System Communications Alarms 
SDV Server Trap 1 (1 Hex) 
Alarm Summary: 
SDV Server Unable to Communicate with DNCS SRM 
Description: 
This alarm occurs when the resource manager of the SDV server failed to acquire 
bandwidth from the DNCS SRM. 
Severity: 
Major 
Service Impact: 
 
An initializing SDV SRM cannot acquire bandwidth for SDV programs. 
 
SDV Servers already running cannot acquire additional bandwidth as needed. 
Check and Correct: 
Possible Causes 
Check and Correct Instructions 
 
The DNCS is not responding. 
 
The DNCS SRM is not responding. 
 
There is a possible network problem 
between the SDV server and the DNCS. 
 
A VASP entry for the SDV server is not 
entered into the DNCS database. 
 
Investigate and troubleshoot your 
network, as this issue could be 
network-related. Contact Cisco Services 
for further assistance. 
 
Verify that the correct VASP ID is entered 
for the SDV server. 
Note: In rare cases, you may see toggling 
between the primary and backup SDV 
servers. This condition should be resolved 
within approximately 1 minute.