Chapter 13    Configuring the System for Satellite and Terrestrial Support 
 
 
 
164 
4017650 Rev C 
Provision a Cable SCS and MPEG Source for 
Satellite and Terrestrial Transport 
For each satellite and terrestrial transport, you must provision a cable Simulcrypt 
Synchronizer (SCS) and MPEG source. Complete the following steps to provision the 
sources. 
1  On the DNCS Administrative Console, click the DNCS tab. 
2  Click the Network Element Provisioning tab. 
3  Click Satellite/Terrestrial Transport. The Satellite Transport Parameters window 
opens. 
4  Click Add New to add a row to the screen. 
5  Complete the fields as follows: 
 
TS ID.  Enter the ID for the satellite transport stream. 
Important: The TS ID for the satellite transport must be unique across the 
DNCS and it should not be the same as any TS ID of either the QAM or SCS 
devices that are configured. 
 
Download Frequency. Enter the frequency to use for the satellite download. 
 
Symbol Rate. Enter enter the symbol rate for the satellite transport in 
symbols per second. 
 
Polarization. From the drop-down list, select the polarization method. 
 
Modulation. From the drop-down list, select the modulation type. 
 
Hub ID. From the drop-down list, select the satellite hub ID. 
 
Cable TS ID. Enter the ID for the cable transport stream modeled using the 
SCS identified earlier.  
Important: The TS ID for the MMDS transport must be unique for the DNCS 
and not conflict with the TS IDs of either QAM or SCS devices. 
 
Home TS. Check this box if it is the home transport stream. You must check 
this box if the UNConfigIndication for the satellite hub needs to carry 
satellite tuning parameters. 
6  Click Save