Operating using ICIM LCD, Continued 
Sub-Menu 5 -- Optical Attenuation/Pump ON/OFF 
The illustration below shows sub-menu 5 of the OptoStar II 1550 nm optical 
amplifier module - Optical Attenuation/Pump ON/OFF. 
 
The default setting of Pump ON/OFF is: ON. The cursor stays on “Set” by default. 
The default factory setting of optical attenuation value is 0 dB.   
• 
To change current pump status 
1.  Press ▲▼ buttons to select pump switch (ON or OFF), and the cursor 
always stays on “Set”; 
2.  Press SET button to save the configuration. 
• 
To select optical attenuation value (with the attenuation range of -3 dB to 0 dB, 
with 0.2 dB step) 
1.  Press ► button to move the cursor to the value field on the right side; 
2.  Press SET button to start the configuration; 
3.  Press ▲▼ buttons to change the value, and press SET button to confirm;   
4.  Press ► button to move the cursor to “Set” on the right side of the screen; 
5.  Press SET button to save the configuration. 
 
 
Continued on next page 
 
 
OL-29666-02   
Operation 