3com link 1000 Manuel D’Utilisation

Page de 152
4-22
C
HAPTER
 4: M
ANAGING
 T
HE
 S
WITCH
 1000
Viewing the Resilient Setup
With the Switch Management screen displayed, 
choose the management level Unit and select the 
RESILIENCE button.
The Unit Resilience Summary screen is displayed as 
shown in 
. This screen shows the cur-
rent resilient link configuration for the unit, and 
allows you to access the Port Resilience screen for 
resilient link pairs.
The following information is displayed:
MAIN Port This read-only field displays the ID of 
the port configured as the main port for the resilient 
link pair.
STANDBY Port This read-only field displays the ID 
of the port configured as the standby port for the 
resilient link pair.
Pair State Active / Both Failed / Unknown / Not 
Available
 This read-only field displays the current 
state of the resilient link pair:
Active — The resilient link pair is enabled and 
operating normally, with both main and standby 
ports capable of carrying traffic.
Both Failed — Although the resilient link is cor-
rectly configured, both links have failed. Check 
for any loose connections or cable damage.
Unknown — The network configuration has 
changed and the resilient link pair no longer con-
forms to the rules.
Not Available — The resilient link pair is disabled.
Figure 4-15   Unit Resilience Summary screen
Active Port Main / Standby / Both Failed This 
read-only field displays which port in the resilient 
link pair is currently carrying traffic:
Main — The pair is operating in its normal state 
with the main port carrying traffic.
Standby — The main port has failed and the 
standby port is carrying the traffic. You should 
rectify the fault as soon as possible. If a main 
port has a higher bandwidth than the standby 
port, traffic will be automatically switched back 
provided no loss of link is detected for two min-
utes. Otherwise, set the Active Port setting in 
the Port Resilience screen (described on 
) to Main to manually switch traffic back.
Both Failed — Both ports of the resilient link pair 
have failed. This could be due to loose connec-
tions or cable damage.