Toshiba tic-lf414c Manuel D’Utilisation

Page de 16
TIC-LF414C 
2
 
Power consumption:  
17W(27VA) or less 
19W(29VA) or less (with PROFIBUS) 
Conformance to European Community Directives: 
EMC directive 89/336/EEC 
The low voltage 93/68/EEC 
PED 97/23/EC (Note 1) 
Note : See Table 1 for detail.
 
Approved hazardous location certifications: 
Model: LF414/LF610F and LF414/LF612F 
cFMus explosion proof: 
FM Class I, Division 2, Groups A,B,C, and D. 
FM Class II, Division 2, Groups E, F and G. 
FM Class III. 
Detector and converter combination: 
LF410/LF610: Combined type for standard 
specification. 
LF410/LF612: Separate type for standard 
specification. 
LF414/LF610F: Combined type with Ex approval 
of Class I, Division 2 (cFMus). 
LF414/LF612F: Separate type with Ex approval of 
Class I, Division 2 (cFMus). 
Mount-Anywhere
 Technology:   
With TOSHIBA’s unique patented magnetic field 
distribution technology, the meter is highly immune 
to upstream flow disturbances.  
A minimum of 1D (one diameter) length of upstream 
straight pipe from the flange is required to maintain 
the performance specification. 
Note : The test results were obtained and demonstrated at 
TOSHIBA's flow calibration facility, Fuchu Japan. 
 Model LF410 and LF414 Detectors 
Mounting style: Wafer type 
Fluid pressure:  
-15 to 300psi, or -1.0 to 20 bar (-0.1 to 2.0MPa) 
Note: The test pressure before shipping from the factory is 
equal to twice the nominal pressure rating of the 
customer specified flange connection during 15 
minutes. 
Connection flange standards: 
ANSI 150, ANSI 300, BS10, BS16, DIN PN10,  
DIN PN16, JIS10K, JIS16K, JIS20K 
Principal materials: 
Case —  
1” to 4” (25 to 100mm): stainless steel  
1/2”, 6”, and 8” (15, 150, 200mm): carbon 
steel 
Linings —  
1/2” to 4” (15 to 100mm):  
Ceramic tube (std.) & Teflon PFA (opt.) 
6” to 8” (150 and 200mm): Teflon PFA 
Electrodes —  
Type-Super smooth, polished with self cleaning 
finish, and non stick shape 
316 stainless steel (std.) 
Hastelloy C equivalent (std.) (in case of Teflon 
PFA lining) 
Note: Electrodes are electro-chemically polished after 
mechanically buffed. 
 
Grounding rings — 316 stainless steel (std.) 
Note: See Table 6 for optional materials and other 
related information. 
Measuring tube material  304 stainless steel (in 
case of Teflon PFA lining) 
Coating —  
1” to 4” (25 to 100mm):  
No coating (stainless steel body). 
1/2”, 6”, and 8” (15, 150, 200mm):  
Corrosion resistant phthalic acid resin coating 
with pearl-gray colored. 
Heat shock resistance: for a ceramic tube detector 
Heating: 
ΔT ≤ 302
°
F/0.5sec (150 
°
C/0.5sec) 
Cooling: 
ΔT ≤ 212
°
F/0.5sec (100 
°
C/0.5sec) 
Note:   The above means that the ceramic tube detector 
withstands the shock of sudden heating 
(temperature difference 150
°C or less per 
0.5seconds) and sudden cooling (temperature 
difference 100
°C or less per 0.5seconds). 
Dimensions and weights: See Figures 3 to 8. 
Cable connection port: for separate type detectors. 
Cable glands — 
LF410 (without cFMus approval): 
Provided as standard, R(PT) 1/2 male 
screws. 
LF414 (with cFMus approval): 
Not provided, 3/4-14NPT male 
screws are required. 
Applicable diameter —  
0.433 to 0.512 inch (11 to 13mm) 
 Model LF610 and LF612 converters 
Input signals 
Analog signal  the voltage signal from detector, 
proportional to process flow rate (for LF612 
separate type converter).