FMI masonry firebox mm44 Manuel D’Utilisation

Page de 44
www.fmiproducts.com
125160-01A
18
supporting Floor system installation
It is the ultimate responsibility of the installer to en-
sure that proper concrete slab supports are used.
 WaRnInG to the licensed design professional 
and/or building contractor: It is your responsibility 
to  be  certain    that  the  Grand  Meridian  can  be 
properly  supported  by  the  combustible  floor 
system on which the fireplace will rest.
For  fireplace  support  foundations  installed  on  con-
crete refer to Appendix I and II (
pages 42 & 43
) for 
specific instructions.
ReBaR loCaTIons
Lay-out  the  position  of  the  fireplace  and  drill  holes 
where the rebar will be located. Secure the #3 rebar 
4 inches into the concrete foundation with ITW Epoxy 
or  Simpson  Epoxy.    Follow  manufacturer’s  instruc-
tions for installation of rebar into slab.
Wood FlooR
Anchorage of fireplace to wood floor construction is 
required. Refer to Figure 29 on page 20 for anchor-
age dimensions. Four anchors are required to attach 
to the sub-flooring framing.
CRaWl sPaCe oR UPPeR FlooR:
For  installation  of  firebox  over  combustible  crawl 
spaces or upper floors, anchorage of the firebox is 
required.  Illustrations  of  examples  of  possible  an-
chorage  methods  are  shown  in  Figures  26  thru  28 
depending upon the type of floor framing. Final meth-
od of anchorage is to be determined by licensed de-
sign professional.
For conventional framing, where the floor joists are 
parallel with the sides of the firebox, the addition of 
floor joists to align with the anchor brackets allows the 
brackets to be directly connected to the floor joists. 
NOTE: Additional floor joists may be required to sup-
port  the  weight  of  the  firebox  and  chimney.  Where 
the floor joists run parallel to the front of the firebox, 
anchorage can be accomplished in like manner as 
shown in Figure 26 using blocking between the floor 
joist.
For floors supported by I-Joists, the method of an-
chorage is illustrated in Figures 27 and 28, page 19. 
Figure 31, page 20 illustrates the general arrange-
ment of anchorage to floor framing.
It is important to take into consideration that the load 
for the Grand Meridian Fireplace must be considered 
as additional dead load that will have to be supported 
by the floor framing. Additional floor joists or I-joists 
may be required as determined by the licensed de-
sign professional.
The dead weights for the fireplace are noted in Table 
I. It is the task and responsibility of the general con-
tractor/installer to see that the proper reinforcement 
for weight loads are made by a licensed design pro-
fessional prior to the fireplace installation.
As  stated  above,  it  is  desirable  to  place  additional 
framing for alignment of anchor rods. Refer to Figure 
29, page 20 for anchor rod locations.
Attach  the  firebox  side  wall  anchors  to  steel  sup-
port frame by inserting all-thread rods through holes 
on the bottom flange on the steel support frame as 
shown  in  Figure  32  and  33,  page  21.  Secure  with 
two Ø 2" o.d. x Ø 9/16" i.d. x 0.10" Washers and two 
1/2"-13 UNC Nuts.
Floor Sheathing 
not shown for 
clarity
Metal Base 
assembly
exaMPle onlY
2x F
loo
R J
oIs
T
2x F
loo
R J
oIs
T
A35 Brackets 
(16 required)
Figure 26 - Floor Joist Installation