13-2 Timer                                                                                                                           LC 1200 Manual                         
 
Wiring  
You will need 22-gauge, 4-conductor plenum-
rated cable for this connection. 
To wire the Timer to the LC unit, refer to Figure 
13.2 and use the following instructions: 
1.  Using the BLACK wire, connect the “-“ 
pin of the Timer to P3-pin5 (Ground) of 
the LC unit. 
2.  Using the RED wire, connect the “+” 
pin of the Timer to P3-pin4 (+12V) of 
the LC unit. 
3.  Using the WHITE wire, connect the 
N.O” pin of the Timer to P1-pin2 
(Perimeter In) of the LC unit. 
4.  Using the GREEN wire, connect the 
C” pin of the Timer to P1-pin1 
(Perimeter Out) of the LC unit. 
 
Figure 13.2 Wiring the Timer