Digital Security Controls Ltd. 09GS260L Manuel D’Utilisation
22
Communicator Troubles on a 1616 / 1832 / 1864 Panel
The General System trouble is the sole trouble that will appear on the keypad LCD when encountered by a Communicator on the
1616 / 1832 / 1864 panel.
1616 / 1832 / 1864 panel.
Firmware Upgrade Default
The firmware upgrade default differs from a full default, in that it is not as comprehensive. The following sections do not default
during a Firmware Upgrade Default:
during a Firmware Upgrade Default:
• Ethernet IP Address
• Ethernet IP Subnet Mask
• Ethernet Gateway IP Address
• DLS Incoming Port
• DLS Outgoing Port
• Ethernet IP Subnet Mask
• Ethernet Gateway IP Address
• DLS Incoming Port
• DLS Outgoing Port
UL Firmware Update
NOTE: In order to comply with UL when this option is enabled, a remote flash upgrade will require an installer to
be on-site.
UL Remote Flash Update Operation
• If this option is enabled, the unit will not perform a flash update unless the unit is restarted with the hardware default jumper
in place.
• The remote server will configure the TFTP settings in the device and will restart the unit.
• If this option is enabled, restarting the unit will not initiate a TFTP session. However, when the hardware default jumper is in
• If this option is enabled, restarting the unit will not initiate a TFTP session. However, when the hardware default jumper is in
place and the unit is restarted, the unit will initiate the TFTP session.
• The first reset after the TFTP session will ignore the hardware default jumper; subsequent resets with the hardware default
will result in a hardware default taking place.
• At the end of the TFTP session the unit shall perform a Firmware Upgrade Default.
Loss of Time and Date
If power was lost completely (AC and battery), the
time and date will need to be re-programmed. Press *.
time and date will need to be re-programmed. Press *.
Re-program Time and Date
Table 5: Communicator Troubles on a 9155 Panel
Trouble Condition
Description
User Action