Commands
7-29
Reader response:
Done
66F Load Default Operating Parameters
Command #66F loads all the factory default operating parameters except RF operat-
ing frequency. Refer to 
for a listing 
of the defaults.
Reader response:
Done
 
All parameters loaded OK
Error
 
A parameter load failed
690N Select Presence Without Tag Report Option
Command #690N enables or disables the presence without tag report option. If the 
presence without tag reporting option is enabled using command #6901, input 
reports are transmitted when a tag presence is detected without the subsequent acqui-
sition of a valid tag. The value for N specifies the reports as shown in 
Note:  These commands only have an effect when the reader is not in MPRR mode. 
Reader response:
Done
Refer to 
 for message format informa-
tion.
692N Select RF Control Algorithm
Command #692N selects the algorithm for turning off RF power when RF-by-input 
control is enabled using command #641 Select RF-by-Input Control. 
The values for N specify the RF control algorithms as shown in 
.
Note:  These commands only have an effect when the reader is not in MPRR mode. 
Table 7-12  Presence Without Tag Report Commands
Command
Report Option
6900
Disable presence without tag reports (factory 
default)
6901
Enable presence without tag reports
Table 7-13  RF Control Algorithm Commands
Command
RF Power Off
6920
On timeout only 
6921
Timeout or tag ID acquired