Configuring the Multiprotocol Rail Reader
8-5
a. Local laws apply. The authorized frequency band for the TransCore MPRR in the 
United States is 911.75 MHz to 919.75 MHz. Contact TransCore if your application 
requires a frequency outside of this range.
Configuring Parameters with Terminal Emulation Software
To configure the MPRR using a PC and terminal emulation software to manually 
enter MPRR host commands, follow the instructions in the section 
. Then, enter the appropriate configuration commands 
through the terminal emulation software on the host. 
See 
 for a detailed description of all available configuration 
commands.
Starting the Terminal Emulation Software
You can use a PC and any terminal emulation software to enter the host commands to 
download flash software, configure reader operating parameters, perform diagnostics, 
and retrieve tag data. The following procedures show examples using Hyper Termi-
nal™, an application included with Microsoft Windows. Most terminal emulation 
applications have a similar sequence for launching.
To start the terminal emulation software
1.
At the command prompt, type your terminal emulation start command; or if 
using Windows Hyper Terminal, select: 
RF attenuation
Full power
64400
SeGo protocol tag operating 
range
Maximum
6451F
Sense output pulse duration
228 ms
67C
Presence without tag reports
Disabled
6900
RF-off control
Timeout or no presence
6922
RF timeout
Never true
693F
Input inversion
Disabled
6940
Serial number
NNNNNN
695
Store hardware configuration
Hardware configuration not 
known
696
Input status change reports
Disabled
820
Automatic periodic RF status 
report
Disabled
830
Table 8-2   MPRR Default Configuration Settings  (continued)
Parameter
Setting
Command