TransCore 0596465PT15 Manuel D’Utilisation
Commands
7-7
Reader response:
Done
102N Select Parity
Command #102N selects the reader parity setting. The factory-default setting is par-
ity disabled. The
ity disabled. The
N
variable specifies parity as shown in
Table 7-3 Select Parity Commands
Command
Data Bits
Parity Selected
1020
8
Disable parity (factory default)
1021
7
Select even parity
1022
7
Select odd parity
Reader response:
Done
Command Group 2
Group 2 commands control the real-time clock which maintains the Encompass 4H
internal time and date. This time and date can be appended to IDs, error messages, and
sensor input reports. An internal battery supports the clock, so time and date are
preserved if main power is lost.
internal time and date. This time and date can be appended to IDs, error messages, and
sensor input reports. An internal battery supports the clock, so time and date are
preserved if main power is lost.
20 Set Time
Command #20 sets the time. Enter the time in the proper format: two-digit decimal
entries with no spaces between characters and using colons as
entries with no spaces between characters and using colons as
delimiters. The entry format is as follows:
20HH:MM:SS or 20HH:MM:SS:hh
where
HH
represents hours (00 to 23).
MM
represents minutes (00 to 59).
SS
represents seconds (00 to 59).
hh
represents hundredths of a second (00 to 99).
:
is the time delimiter.
If hundredths of a second is not specified, the reader sets the hundredths register to 00.
Reader response: