TransCore 0596465PT15 Manuel D’Utilisation
Commands
7-23
shows the output0 and output1 open/closed conditions for the output status
displays for readers in IAG applications.
Table 7-9 Open/Closed Conditions for Output Status (IAG Applications)
Output
Status
Output0 Wire Pair
Output1 Wire Pair
Orange
Jumper to
Black of
Brown/Black
Brown/Black
White
Jumper to
Black of
Green/Black
Green/Black
O0
Closed
Open
Closed
Open
O1
Open
Closed
Closed
Open
O2
Closed
Open
Open
Closed
O3
Open
Closed
Open
Closed
shows the input0 and input1 open/closed conditions for the input status
displays.
Table 7-10 Open/Closed Conditions for Input Status
Input
Status
Input0 Wire Pair
Input1 Wire Pair
Green/Red
Blue/Black
I0
Open
Open
I1
Closed
Open
I2
Open
Closed
I3
Closed
Closed
527 Display RF Status
Command #527 displays the current status of the RF module. The reader response
indicates whether RF is controlled externally by the host, set by command #640N RF
Control, or internally by input set by command #641. Command #527 also displays
the current RF status and the uniqueness timeout.
indicates whether RF is controlled externally by the host, set by command #640N RF
Control, or internally by input set by command #641. Command #527 also displays
the current RF status and the uniqueness timeout.
O2
Closed
Open
Open
Closed
O3
Open
Closed
Open
Closed
Table 7-8 Open/Closed Conditions for Output Status