Advance Security Inc TR06AM Manuel D’Utilisation

Page de 24
MAY/23/ 2003 
RST771IN 
21 
3. Press the transmitter 
  and 
  button at the same time to set the “Timer Checking Type”. [3] LED flash, 
        [3] chirp to confirm this setting   
4. Once you complete step 3, you can adjust and test “Start Timer” as below: 
START TIMER PROGRAMMING: (TEST and ADJUST) 
While the system stay in Start Feature “II” programming mode, 
1. Press the 
  button twice on the transmitter to start the vehicle.   
2. If everything goes well: 
a. Press the '
 button twice on the transmitter to stop engine running. You have been completed this 
programming successfully. 
b. Press 
  button on the transmitter to exit the program mode. There will be 3 long chirps & 3 parking 
light flashes for confirmation.   
3. If the crank time is too long, (Engine already successfully running, while still cranks): 
a. Press the 
  button twice on the transmitter to stop engine running. 
b. Press the 
  button on the transmitter to set proper “Start Timer”. The chirp & LED pause will confirm 
this enter. (Decrease “Start Timer” is necessary.) 
c. Repeat the step1 – 4. 
4. If the crank time is too short, (Engine not running, while stops cranks): 
a. Press the 
  button twice on the transmitter to stop engine running. 
b. Press 
  button on the transmitter to set proper “Start Timer”. The chirp & LED pause will confirm this 
enter. (Increase “Start Timer ” is necessary.) 
c. Repeat the step1 – 4. 
 
TEST MODE 
In this test mode, this system can test the Zone 2 (Instant ground trigger), the Zone 3 (Door trigger), and the 
Zone 1 & Zone 4 (2 stage shock sensor) sensitivity. The installer can save time to test the 2 stage shock 
sensor sensitivity and sensor without using the traditional arming/disarming procedures to test the sensors.   
Enter: 
1. Turn the Ignition switch ‘ON/OFF’ 3 TIMES and stay in OFF position.   
2. Push the Valet switch 10 times and hold it until five chirps with a long chirp is hearing then release the 
valet switch. You are now in the Start feature ‘II’ programming mode. 
a. Test the Zone 2 / Instant Ground Trigger & Zone 3 / Door Trigger: 
Press and release the transmitter 
  and 
  button at the same time once. [1] LED flash, [1] 
siren/horn chirp to indicate your are in Zone 2 / instant ground trigger and Zone 3 / Door trigger test 
mode. 
Trigger sensor 
Siren chirps 
Zone 2 / Instant Ground trigger (H5/4 Blue wire) 
Zone 3 / Door trigger (H5/6 Green or H5/7 Violet wire) 
b. Test the Zone 1 & Zone 4 / Two Stage Shock Sensor (Connected to H7 4 Pin Plug)
Press and release the transmitter 
  and 
  button at the same time again. [2] LED flash, [2] 
siren/horn chirps to indicate your are in the shock sensor (connected to H7 4 pin plug) test mode. 
1. Activate the warn-away (first stage of the shock sensor / Zone 1), system will emit a short chirp. 
2. Activate the full alarm (second stage of the shock sensor / Zone 4), system will emit a long chirp. 
3. Continue to test the shock sensor until reach the proper sensitivity. 
 
RETURN TO FACTORY DEFAULT SETTING: 
1. Turn the ignition ON then OFF 3 TIMES and stay in OFF position. 
2. Push the Valet switch 12 times and hold it until six chirp with a long chirp is hearing then release the valet 
switch. You are now in the “Return To Factory Default Setting” programming mode. 
ALARM FEATURE ALL RETURNS TO FACTORY DEFAULT SETTING: 
3. Press and hold the 
 
and
 
  button at the same time on the transmitter for 6 seconds, there will be a 
confirmation six chirp with 3 long chirp to confirm the system “Alarm Feature I & II & III Programming all 
returns to factory default setting. 
START FEATURE ALL RETURNS TO FACTORY DEFAULT SETTING: 
4. Press  the 
 
first, within 3 seconds press and hold the 
 
and
 
 button at the same time on the 
transmitter for 6 seconds, there will be a confirmation six chirp with 3 long chirp to confirm the system 
“Start Feature I & II Programming all returns to factory default setting.