2-7
 
WARNING: Disconnect primary power prior to servicing.
Section 2 Installation / Initial Turn-On 
Maxiva UAX Transmitter Indoor System
User Manual
2.5
AC/Ground connections
There are two AC power connections needed for the UAX Indoor System. 208-240VAC 
is required and connected inside the AC access panel shown in Figure 2-4. See the AC 
wiring diagram843-5602-148 in the UAX drawing package 943-5276-170.
Figure 2-4  UAX AC Mains Connections (top of cabinet, access panel cover removed)
An additional 120VAC connection (L1, N & ground) is required at the distribution box 
on the top of the transmitter. The connection is made at the side of the box with 1/2" 
conduit fittings supplied by thecustomer. The distribution box is shown in Figure 2-5.
Figure 2-5  120VAC Connection
208-240VAC
Input
Safety
Ground
AC Connections
AC
Input
120VAC
Distribution Box
120VAC