Tyco Safety Products/Sensormatic AMS9050 Manuel D’Utilisation

Page de 31
Preliminary 
Installation 
The AMC-7000 Metal Foil Detection kit (ZPMETAL-
DET) consists of the following: 
Part Qty. 
Part 
Number 
Metal detection enclosure 
0304-3048-01 
Mounting bracket, Left 
0505-4642-01 
Mounting bracket, Right 
0505-4642-02 
Tx/Rx cable 
0652-0467-02 
Power supply/RS-485 cable 
0652-0468-01 
Wired Sync 
0652-0467-01 
Connector assy, Aux/WS (5-pin) 
0304-2887-01 
Connector assy, Alarm/comm (8-pin)  1 
0304-2952-01 
Romex conduit connector 
6010-0107-01 
Nut 4 
5828-0400-011 
 
For Pre-existing Systems 
If you are installing an AMC-7000 on a Ultra•Exit 
system that is already installed and working, do the 
following before turning off the system and starting 
the installation process. 
1.  Perform a tag-pick test so that you can compare 
system performance afterwards. 
2.  Use a tag or label to determine which pedestal 
is A and which is C. Use the noise screen on 
the configurator to determine which is which. 
3.  Save the system settings to a file. 
Wiring the AMC-7000 
Connect the following cables to the AMC-7000 
Metal Foil Detection Board. Use the four Romex 
conduit connectors when connecting the cables to 
the AMC-7000 enclosure. Refer to Figure 1 and 
Figure 2. 
AMC-7000 
Connector 
Cable P/N and Name 
P2 
 
(Ant. 1 OUT) 
0652-0242-01 
(AMS-9050 Tx/Rx) 
P1 
 
(Ant. 1 IN) 
0652-0467-02 
(AMC-7000 Tx/Rx) 
P8
  
(+12V DC GND) 
0652-0468-01 
(AMC-7000 Power Cable) 
P14 
 
(Network RS485) 
0652-0468-01 
(AMC-7000 Power/RS-485) 
P5 
 
(Wired Sync) 
0652-0467-01 
(AMC-7000 Wired Sync) 
P3
  
(Ant. 2 IN) 
0652-0467-02 
(AMC-7000 Tx/Rx) 
P4
  
(Ant. 2 OUT) 
0652-0242-01 
(AMS-9050 Tx/Rx) 
P6/P7
1
  
(Peripheral RS-485) 
RS-485 
P9
2
 
 
(Relay) 
Relay 
1  This connector is cabled only when the AMC-
7000 is connected to an RS-485 network. 
2  This connector is cabled only when the AMC-
7000 is connected to an optional relay-activated 
device (such as a security camera or paging 
device). 
Wiring the Ultra•Exit Antennas  
Connect the following cables to the Ultra•Exit 
antennas. Refer to Figure 1
Connector 
Cable P/N and Name 
P5 on Ant. A
 
(Alarm/Com) 
0652-0243-01 (AMS-9050 Com) 
from P92 on AMS-9050 
P1 on Ant. A
 
(Tx/Rx) 
0652-0242-01 (AMS-9050 Tx/Rx) 
from P2 on AMC-7000 
P5 on Ant. C
 
(Alarm/Com) 
0652-0243-01 (AMS-9050 Com) 
from P93 on AMS-9050 
P1 on Ant. C
 
(Tx/Rx) 
0652-0242-01 (AMS-9050 Tx/Rx) 
from P4 on AMC-7000 
 
AMC-7000 INTEGRATED METAL Foil DETECTION 
8200-2609-01, REV. 3a 
INSTALLATION GUIDE 
18 OF 31