Tyco Safety Products/Sensormatic AMS9050 Manuel D’Utilisation

Page de 31
Preliminary 
Installation Features 
The AMS-9050 controller provides the following 
installation features: 
- Auto 
Synchronization 
- Wired 
Synchronization 
- Transmitter 
Current 
Control 
- Controller 
Mounting. 
Auto Synchronization 
Auto synchronization occurs during power up or 
system reset. Auto sync can have different 
outcomes depending on whether or not nearby 
EAS transmitters are detected, they are properly 
aligned to the ac-derived timing of the controller, or 
too much ambient noise exists. 
No transmitters detected. 
During initialization, the 
controller determines if EAS transmitters are 
nearby. If none are found, transmitter delay is set 
to zero if this is the initial power on, or set to the 
value stored in the controller if not the initial power 
on. 
Transmitters detected: 
-  Transmitters detected and aligned. If 
transmitters are correctly aligned, the 
transmitter delay is calculated and stored in the 
controller for reference. 
-  Transmitters detected and not aligned. If 
transmitters are not aligned, the transmitter 
delay is set to zero if this is the first power on of 
the controller, or set according to the value 
stored the controller if not the initial power on. 
Too much ambient noise. 
During initialization, the 
controller locates other nearby EAS transmitters. 
-  If ambient noise prevents the controller from 
locating nearby EAS controllers and if this is the 
first power on of the controller, transmitter delay 
is set to zero. 
-  If this is not the first power on of the controller, 
the zero crossing delay stored in the controller 
is used. 
Note:
 The controller stores the zero crossing delay 
for when the controller could not determine a 
reliable lock during subsequent power cycles. 
Instead of using zero for the delay, the controller 
uses the stored zero crossing delay. 
Wired Synchronization 
If a wired Tx sync device is connected to the 
controller, the controller automatically uses its 
signal as the timing reference instead of the ac 
line. The service configurator indicates that wired 
sync is active. 
Transmitter Current Control 
This function enables you to inhibit the transmitter 
and/or alarms of the desired pedestal using the 
Tx/Alarms inhibit switch located in the top of 
antennas that support this function. 
Controller Mounting 
The controller has a built-in flange used to attach 
the controller to a wall or ceiling using suitable 
hardware. 
-  Ceiling attachment requires plywood be first 
attached to the ceiling and then the controller 
attached to the plywood. 
-  Structure and mounting hardware must support 
25.6kg (56.5 lbs) or four times the weight of the 
controller assembly. 
AMC-7000 INTEGRATED METAL Foil DETECTION 
8200-2609-01, REV. 3a 
INSTALLATION GUIDE 
7 OF 31