Service Features
The AMS-9050 controller provides the following
service features:
- “Tag Too Close” function
- Service
service features:
- “Tag Too Close” function
- Service
configurator
software
- Internal
diagnostics
- LED system status indicator
- Remote diagnostics via an Ethernet or RS-485
- Remote diagnostics via an Ethernet or RS-485
network
- Transmit/Alarm Inhibit function
- Detachable cable access panel.
- Detachable cable access panel.
“Tag Too Close” function:
Using the service
configurator, you can select the “tag-too-close”
function to help prevent false alarms. With this
function selected, the red lamp on top of the
antenna blinks twice every four seconds for one
minute when the system detects one or more
stationary tags or labels are too close to it. The
lamp goes out when these tags/labels are moved
away from the system.
function to help prevent false alarms. With this
function selected, the red lamp on top of the
antenna blinks twice every four seconds for one
minute when the system detects one or more
stationary tags or labels are too close to it. The
lamp goes out when these tags/labels are moved
away from the system.
Tagged items must be kept at least 1.5m (5ft) away
from all sides of the antenna.
from all sides of the antenna.
Service configurator software:
Operating
software required: Windows
®
95, 98, NT, 2000, or
XP.
Service configurator software downloaded to a
laptop computer is required to setup and
troubleshoot the controller. The service
configurator enables you to:
- Set
laptop computer is required to setup and
troubleshoot the controller. The service
configurator enables you to:
- Set
antenna
configurations
- Customize detection for each antenna
- Monitor transmit and noise levels from each
- Monitor transmit and noise levels from each
antenna
- Monitor transmit current from each antenna
- Customize alarm setup
- Turn off transmitters
- Monitor temperature inside the controller
- Download new software features/updates to
- Customize alarm setup
- Turn off transmitters
- Monitor temperature inside the controller
- Download new software features/updates to
flash memory
- Provide a system error report.
Note:
Special tools are not required when installing
the controller as long as the antennas are installed
in a reasonable noise environment and local
transmitters are properly adjusted.
in a reasonable noise environment and local
transmitters are properly adjusted.
Note:
If default settings are changed, you do not
need to turn the controller off and on to store them.
Internal diagnostics:
- The service configurator displays the operating
- The service configurator displays the operating
current for each antenna. Operating current is
15A peak for all countries.
15A peak for all countries.
- The service configurator displays ambient
temperature within the controller.
- The hardware supports software with a remote
command to reset the system.
- Hardware within the controller protects it from
runaway software.
LED system status indicator:
An LED system
status indicator on the controller indicates the
following:
following:
- Green flashing (system on and okay)
- Yellow flashing (performance downgraded;
- Yellow flashing (performance downgraded;
service recommended)
- Red flashing in a particular sequence (fault
detected, call for service)
The number of red flashes identifies a digit in a
two-digit alert code (for example, four flashes is
the number four). The start of an alert code is
indicated by a long LED interval. Then the first
digit of the code occurs, followed by a short
delay, followed by the second digit.
Alert codes are listed on page 13.
The number of red flashes identifies a digit in a
two-digit alert code (for example, four flashes is
the number four). The start of an alert code is
indicated by a long LED interval. Then the first
digit of the code occurs, followed by a short
delay, followed by the second digit.
Alert codes are listed on page 13.
Remote diagnostics via an Ethernet or RS-485
network:
network:
Using a service laptop, service personnel
can dial-up and connect to a network of controllers
to troubleshoot problems and change controller
parameters (see page 14).
to troubleshoot problems and change controller
parameters (see page 14).
Transmit/Alarm Inhibit function:
This function
enables you to inhibit the transmitter and/or alarms
of the desired pedestal using the Tx/Alarms inhibit
switch located in the top of antennas supporting
this function.
of the desired pedestal using the Tx/Alarms inhibit
switch located in the top of antennas supporting
this function.
Detachable cable access panel:
By removing six
screws from the perimeter of the cable access
panel and disconnecting cables, the electronics
can be removed for easy servicing or replacement
without disturbing cabling.
panel and disconnecting cables, the electronics
can be removed for easy servicing or replacement
without disturbing cabling.
AMC-7000 INTEGRATED METAL Foil DETECTION
8200-2609-01, REV. 3a
INSTALLATION GUIDE
8 OF 31