Tyco Safety Products/Sensormatic AMSUSUPB Manuel D’Utilisation
ULTRA 1.5 METER ABS PEDESTAL SYSTEM
8200-1048-06, REV. A
INSTALLATION GUIDE
18 of 44
*8200-1048-06*
If you are replacing the secondary receiver board, you must complete the following steps:
1. Attach the 3-position connector to the upper antenna coil cable as shown in Table 13. Plug the cable into
the top coil connector, P1, on the receiver board.
Table 13. Secondary antenna top coil connections
Pin
Color
Signal name
1
Black
Secondary top coil return
2
Red
Shield
3
White
Secondary top coil
2. Attach the 3-position connector to the lower antenna coil cable as shown in Table 14. Plug the cable into
the bottom coil connector, P3, on the receiver board.
Table 14. Secondary antenna bottom coil connections
Pin
Color
Signal name
1
Black
Secondary bottom coil return
2
Red
Shield
3
White
Secondary bottom coil
Step 3: Connecting AC power
To connect the system to AC power, complete the following steps:
CAUTION: A 15A, two-pole, ganged disconnect device, which also provides short circuit and overload
protection, and has a minimum 3 millimeter open circuit clearance, in accordance with the National
Electric Code and applicable local codes must be installed by a licensed electrician at a location
readily accessible to the equipment. If the only line providing power is the primary/L1, you can use a
single-pole breaker.
protection, and has a minimum 3 millimeter open circuit clearance, in accordance with the National
Electric Code and applicable local codes must be installed by a licensed electrician at a location
readily accessible to the equipment. If the only line providing power is the primary/L1, you can use a
single-pole breaker.
1. Locate the voltage shunt, 2109-0062-01, which is in a bag taped inside the primary pedestal enclosure.
WARNING:
Risk of electric shock
Ensure that the system is not powered before moving the shunts.
2. Select the proper voltage for the site using the shunt, 2109-0062-01. The default setting is 240Vac.
For the location of J5, see Figure 8.
Figure 7. Voltage settings and shunts
120 Vac: J5 shunt IN
240 Vac (Default): J5 shunt OUT