HM Electronics Inc XCVR2G4A Manuel D’Utilisation

Page de 161
User Guide | FreeSpeak II™ 
 
Page 73 
 
 
 
Figure 6-39 Second partyline connection type menu 
5)
 
Select ‘OFF’ to disable partyline termination on the port. This will apply 
regardless of the type of partyline connected to the port. For example if 
the partyline is connected to an MS-702 master station with termination 
enabled the Base station termination must be disabled. 
6)
 
The changes are saved and applied automatically five seconds after the 
last time the setup/enter encoder was pressed or turned. The front-panel 
display flashes to indicate that the changes are being saved and applied.  
The Base station automatically sets the port’s termination, gain, and call signaling 
options for the selected partyline type.  
6.15.2
 
To configure the Noise Gate for a partyline port 
The noise gate sets a cutoff level below which audio input is ignored in order to 
avoid transmitting low levels of background noise. The noise gate can be set to a 
value in the range -70dB to -10dB when enabled. 
1)
 
Select PORTS from the main menu, then select PLCHA or PLCHB from the 
AVAILABLE AUDIO port menu which appears. 
2)
 
The port configuration menu is displayed. Scroll rightwards to display the 
second page of the menu. 
3)
 
Select GATE. The Noise Gate menu is displayed. 
 
Figure 6-40 Partyline noise gate menu 
4)
 
Scroll to the ‘STATE’ option and press the setup/enter encoder to display 
the noise gate state menu.