Lectrosonics Inc SMV Manuel D’Utilisation

Page de 20
10
SM
Professional Audio Products Since 1971
with 200 Series, 100 Series and IFB analog receivers,
plus some other analog wireless receivers (contact the
factory for details).  Setting the Compatibility Mode of the
transmitter to match the receiver is easily done via the
Control Panel.
Note
The unit comes from the factory configured as a 400 Series
transmitter.
1) Set the receiver’s audio controls to minimum.
2) Power up the SM and observe the Boot
Sequence.  If the Compatibility Mode for the
SM does not match the corresponding
receiver, then power off the SM transmitter.
3) From a power off condition, hold down the Up
arrow, then simultaneously press the AUDIO
and FREQ buttons.
4) The LCD will display the current Compatibility
Mode.  Use the Up or Down
arrow buttons to reset the
Compatibility Mode to
match the corresponding
receiver.
The following Compatibility
Modes are available:
• 100 Series mode:
 CP 100
• 200 Series mode:
 CP 200
• Mode 3 (Contact dealer for details):  CP 3
• 400 Series mode:
 CP 400
• IFB Series mode:
 CP IFB
5) Press the AUDIO or FREQ to exit this function.
The Compatibility Mode selected in Step 4 will
be the current Compatibility Mode until reset
using this procedure.
SETTING TRANSMITTER  OPERATING
FREQUENCY
The Operating Frequency of the SM can be displayed
either in MHz or as a two-digit hexadecimal number.
POWER UP AND BOOT SEQUENCE
1) Ensure that a good battery is installed in the
unit.  (See 
Battery Installation.)
2) Simultaneously press the AUDIO and FREQ
buttons.  As the unit turns on, the Modulation
LEDs and PWR LED all glow red, then they all
glow green.  Then, they revert to normal
operation, i.e., the Modulation LEDs glow
according to the AUDIO level setting and the
PWR LED glows green (providing the battery
is in good condition).
The LCD displays a bootup sequence which
consists of four screens:
Company Name:
Lectro
Frequency Block (bXX) and
Firmware Version (rX.X):
b21r1.1 (typ)
Compatibility Mode:
CP 400 (typ)
Frequency:
550.300 (typ)
POWER DOWN
1) Simultaneously press and
hold the AUDIO and FREQ
buttons while observing
that the word “Off” appears
in the LCD along with a
counter.
2) When the counter reaches
“0”, release the AUDIO and
FREQ buttons to turn off
the unit.
Note
If the AUDIO and FREQ buttons are released before the counter
reaches “0,” the unit will not turn off.  Instead, it will stay energized
and the display will return to the previous screen.
SELECTING THE  COMPATIBLITY  MODE
All Digital Hybrid Wireless™ receivers are capable of
working with the Lectrosonics SM transmitter. By select-
ing the proper compatibility mode, the SM will also work
OPERATING INSTRUCTIONS
oFF . . .3
Initial Power Off Timer
Screen
End Power Off Timer
Screen
oFF . . .0
AUDIO Button
LCD
FREQ Button
Modulation LEDs
PWR LED
Control Panel
AUDIO Button
LCD
FREQ Button
UP Arrow
CP 400
400 Series or Digital
Hybrid Wireless™
Compatibility Mode