Eccel Technology Ltd BIORADRDR0200 Manuel D’Utilisation
72
8.5.4 Testing
[R9-1] All PCBs shall be electrically tested per the IPC-9251 specification.
[R9-2] All PCBs shall have AOI up to the quality level which is defined by the Manufacturer’s AOI testing equipment.
[R9-3] At least 4% of the PCBs should have a manual visual inspection.
[R9-4] All devices shall have undergone functional testing defined by Eccel and described in a separate document.
8.5.5 Documentation
[R10-1] The hardware version of the PCB shall be ‘BioRad RFID Reader v2.0’ which is read as BioRad RFID Reader
version 2 revision 0.
version 2 revision 0.
[R10-2] The firmware version used for programming shall be ‘RFID A1-1 v2.1’ which is read as RFID A1-1 version 2
revision 1.
revision 1.
8.5.6 Packaging and Delivery
[R11-1] Each PCB shall be dismantled and deburred.
[R11-2] Each PCB shall be individually packaged in a way that each package will be:
• Sealed.
• Providing antistatic shielding in the way that the packaged product can be carried outside ESD Protected
• Providing antistatic shielding in the way that the packaged product can be carried outside ESD Protected
Areas.
[R11-3] Each batch shall be delivered with a certificate of quality control.
[R11-4] Each batch shall be delivered with a certificate of RoHS conformity.
[R11-5] Each PCB shall be delivered without accessories of automatic mounting of components.
[R11-6] Each PCB shall have all technical edges removed.
[R11-7] The PCB shall not be delivered in a panel.
8.5.7 Programming
[R12-1] Each PCB shall be programmed with firmware pointed in chapter 8.5.5.