GETTING STARTED
WIRELESS SENSOR
1.  Remove the battery door of the sensor.
2.  Insert 2 x AA size batteries into the battery compartment. Make 
sure you insert them the right way according to the polarity 
information marked on the battery compartment.
3.  Close the battery door.
Note:
 - Once the channel is assigned to one sensor, you can only 
change it by removing the batteries or resetting the unit.
 - Avoid placing the sensor in direct sunlight, rain or snow.
MAIN UNIT
1.  Remove the battery door of the main unit.
2.  Install 4 new AA size batteries according to the polarity 
information marked on the battery compartment and then press  
[ RESET ] key by using a metal wire to reset the unit. 
3.  Close the battery door.
4.  Once the batteries are installed, all the segments of the LCD will 
be shown.
Note:
To avoid the wireless sensor and main unit pairing failure, please 
power up the sensor/s first, and then press 
[ RESET ] key on the 
main unit (no need on sensors).
INDOOR TEMPERATURE AND HUMIDITY FUNCTION
1.  Press
 [ °C / °F ] key to switch between °C / °F. Decimal point is 
effective for both settings.
2.  When the temperature is below -40°F or above 158°F, “
Lo” or 
Hi” will be displayed respectively. The humidity display will show 
--”.
Temperature below -40°C 
Temperature above 70°C
  
3.  When the humidity is below 1% or above 99%, “
Lo” or “Hi” will be 
indicated respectively.
Humidity below 1% 
Humidity above 99%
 
COMFORT INDICATION
The comfort indication is a pictorial indication based on indoor air 
temperature and humidity in an attempt to determine comfort level.
Too cold
Comfortable
Too hot
Note:
 - Comfort indication can vary under the same temperature, 
depending on the humidity.
 - There is no comfort indication when temperature is below 0°C 
(32°F) or over 60°C (140°F).
TEMPERATURE & HUMIDITY TREND
The temperature & humidity trend indicator shows the trends of 
changes in the forthcoming few minutes. Arrows indicate a rising, 
steady or falling trend.
Arrow indicator
Trend
Rising
Steady
Falling
TEMPERATURE AND HUMIDITY CALIBRATION
1.  In normal mode, press and hold 
[ TUNE ] key for 2 seconds to 
enter temperature and humidity calibration mode in which the 
current outdoor channel or “
IN” icon will flash. Press [ CHANNEL 
/ + ] or [ MEM / - ] key to choose for INDOOR or different 
CHANNEL.
Choose Channel 
  
2.  Press 
[ MODE ] key again to switch between temperature and 
humidity. Press 
[ CHANNEL / + ] or [ MEM / - ] key to adjust the 
value.
3.  When finished, press 
[ TUNE ] key for 2 seconds or leave the unit 
for 60 seconds to return to normal mode.
4.  Pressing 
[ MODE ] key for 2 seconds during temperature and 
humidity calibration mode will reset the value to the actual or 
uncalibrated measurement.
5.  Reset the temperature and humidity values for each channel 
individually. There is no batch reset.
6.  Calibration mode sequence: channel → temperature → humidity
7.  In temperature calibration mode, press 
[ CHANNEL / + ] key or  
[ MEM / - ] key to modify 0.1 °C or °F of the value. Long press to 
quick-adjust the value.
Temperature calibration mode
8.  In humidity calibration mode, press 
[ CHANNEL / + ] or  
[ MEM / - ] key to modify 1% of the value. Long press to quick-
adjust the value.
Humidity calibration mode
9.  If the current reading of the selected channel displays the flashing 
--”, “Hi” or “Lo”, it will be impossible to adjust. Pressing  
[ CHANNEL / + ] or [ MEM / - ] key will not change the value.
10. If re-enter temperature and humidity calibration mode, the 
adjusted value will reset to the original value.
11. The comfort indication is based on calibrated temperature and 
humidity values to calculate.
MAX/MIN TEMPERATURE AND HUMIDITY RECORD
The unit preserves the MAX/MIN temperature and humidity records 
since the last manual reset. 
1.  In normal mode, press 
[ MEM / - ] key once to show the current 
maximum temperature and humidity values; press again to show 
the minimum values; press the third time to return to normal 
mode.
2.  When the MAX/MIN records are shown, the display will return to 
normal mode after leaving the unit for 5 seconds.