Nova-243 Outdoor LTE TDD Base Station Installation Guide 
 
 
Installation Environment 
2.3
2.3.1  Locational Requirements 
Environments  with  high-temperatures,  harmful  gases,  unstable  voltages,  volatile 
vibrations, loud noises, flames, explosives, and electromagnetic interference (large radar 
stations, transmitting stations, transformer substations) are not suitable for the operation 
of Nova-243, and thus should be avoided.   
Places prone to have impounded water, soaking, leakage, or condensation, should also 
be avoided.   
Factors  like  climate,  hydrology,  geology,  earthquake,  electric  power,  and  transportation 
should be taken into consideration  in  the construction process  so that a proper location 
can be chosen  to meet the communication engineering environmental requirements, as 
well as the technical requirements of network planning and communication equipment. 
2.3.2  Environmental Requirements 
gives the base station’s environmental requirements on temperature, humidity, 
and voltage.   
Table 2-2 Environmental Requirements of the Base Station 
Item 
Range 
Typical value 
Temperature 
-40°C to 55°C 
25°C 
Relative humidity (no condensation)  0% to 100% 
5% to 95% 
Safety voltage 
42 V to 58 V 
48 V 
 
2.3.3  Power Requirements 
Nova-243 TDD base station adopts -48V DC power supply. For the safety and reliability of 
device, we have the following suggestions. 
 
Remote DC power supply, in general, AC power supply is 100V ~ 270V, the distance 
of AC power supply to the device is less than 30 meters. 
 
If the static exceeds a certain range, it will lead to great damage to the circuit and the 
whole device. 
 
Personnel Requirements 
2.4
The installation personnel must master the basic safe operation knowledge, through the