Protective Bonding Test 5 A / 0.2 A (R
PE
)
The protective bonding test measures the resistance between PE terminal of test
socket and PROBE 1 terminal. This test applies to class I appliances only.
Remarks:
To obtain correct protective bonding test results you must have
socket and PROBE 1 terminal. This test applies to class I appliances only.
Remarks:
To obtain correct protective bonding test results you must have
compensated (zeroed) the test lead, see the section “Test lead
compensation” on page 15.
compensation” on page 15.
Connect the appliance and the earth bond test lead according to the figure 6
or 7.
You should use the lower test current 0.2 A for certain appliances. Please
refer to local appliance test standards and guidance material.
During the measurement flex the flexible cord along its length to help find
any broken conductors or poor quality joints.
Figure 6: Protective bonding test connections at appliance with mains plug
Figure 7: Protective bonding test connections at permanently connected
appliance