Beha Amprobe GT-800 STD KITVDE-tester 4472062 Manuel D’Utilisation
Codes de produits
4472062
GT-600/GT-800 Instruction Manual
41
Safety Extra Low Voltage Test (SELV)
The test measures the safety extra low voltage between two accessible
conductive parts of tested appliance.
conductive parts of tested appliance.
Figure 34: SELV test connection
Display
explanation:
Figure 35: Display in SELV test
1 ...... “PELV/SELV” soft menu key, for selection of measurement function
SELV or PELV).
2 ...... “LIM” soft menu key, for pass/fail limit value setting (standard values
are 25 or 50 V).
3 ...... Test result status ( ... result OK, X ... result not OK).
4 ...... Pre-set pass/fail limit value.
5 ...... Function selected by the rotary switch and the “SELV/PELV” key.
6 ...... Test result and unit.
4 ...... Pre-set pass/fail limit value.
5 ...... Function selected by the rotary switch and the “SELV/PELV” key.
6 ...... Test result and unit.
Specific information that can be shown on the display
Information displayed
Description
<10.0V
SELV value lower than 10.0 V.
>150.0V
SELV value higher than 150.0 V. Remove the
voltage.
voltage.
In order to save displayed measurement result, press the “SAVE” function
key (F5) twice, for further instructions see the “Memorizing example”
section.
section.