SSI America Video Gaming Accessories 9200 Manuel D’Utilisation

Page de 68
Model 9200 Programmable Dual-loop Controller
SSi Manual SERIES 9200
17                                              Programmable Dual-loop
•  The Stop button “stops” the recipe program that is currently displayed. “Stop” means exactly
that! It stops the program. It is NOT a “hold” button. See “hold” below. To re-start the
program if it has been “stopped” you must use the “load” button, enter the recipe number, and
then highlight the segment number of the recipe that you want to start with and initiate “Run”.
•  The Hold button places the displayed recipe program in “hold”. Once a decision is made that
affects the recipe it may be continued by pressing the Cont button.
•  The Cont button re-starts the displayed (active) recipe, where it was placed in “Hold” at .
•  The Alm Ack displays the Alarm Screen. From here you can acknowledges the “ALARM”, in
most cases it will be acknowledging “End of Soak”. The alarm must be acknowledged to allow
the program to “go” to the next step.
•  The Esc button returns you to the “default” display screen.
Quench  / Zone Instrument Assignments (Read-only)
The “Quench / Zone Instrument Assignments ” display shows two groups of information, both of which are
dependent on “CONFIGURATION” or “OPT CODE” use.  The quench portion will only display if the quench
“opcode” was executed in a program.  This will then show the total quench time, the time remaining, and
the quench speed.  The zone group will display the process variables  that have been assigned in the zone
assignment configuration.