Ultimate Technology 600 POS Manuel D’Utilisation

Page de 81
  
 
Series 600 POS Keyboard 
 
 
 
 
47
  
 
 
Table 5.  Remote Programming Mode Commands
 
OP CODE 
(HEX) 
MNEMONIC/DESCRIPTION 
COMMAND/ACKNOWLEDGEMENT 
B0 
LIGHT 
 
Provides on/off control for keyboard light 
emitting diode (LED) indicators.  PC mode 
for NUM and CAP Lock lights is default. 
COMMAND: 
B0Lx<CR> 
 
B0 
= Op Code 
= lamp 
= on/off 
<CR> 
= terminate command (0D hex)   
 
 
 
L: 
0, 1, 2, 3, P in ASCII, where 0 = all.  P is 
used for PC emulation of NUM and CAPS 
Lock 
  
x: 
PC mode 
 
1 = on; 0 = off 
 
ACKNOWLEDGEMENT: NONE