Ultimate Technology 600 POS Manuel D’Utilisation

Page de 81
  
 
Series 600 POS Keyboard 
 
 
 
 
49
  
 
 
Table 5.  Remote Programming Mode Commands 
OP CODE 
(HEX) 
MNEMONIC/DESCRIPTION 
COMMAND/ACKNOWLEDGEMENT 
B3 
RDERROR 
 
Sends all error information to main port for 
output. 
COMMAND: 
B3<CR> 
 
B3 
= Op Code 
<CR> 
= terminate command (0D hex)   
 
Sends all error log information contained in the non-
volatile memory (NVRAM) out the main port. 
 
ACKNOWLEDGEMENT: NONE 
B4 
COMMIT 
 
Writes programming changes to the 
NVRAM.  Always apply the COMMIT 
command after programming the keyboard 
to save the changes in the NVRAM.  
Failure to use the COMMIT command will 
result in the loss of the changes the first 
time power is removed from the keyboard. 
COMMAND: 
B4<CR> 
 
B4 
= Op Code 
<CR> 
= terminate command (0D hex)   
 
ACKNOWLEDGEMENT: NONE 
 
B5 
RESET 
 
Resets keyboard after downloading 
configuration.  On receipt of this command 
the unit does a warm boot. 
COMMAND: 
B5RST<CR> 
 
B5 
= Op Code 
<CR> 
= terminate command (0D hex)   
 
ACKNOWLEDGEMENT: NONE 
B6 
 
KSSND 
 
Used to select when keyswitch 1, 2 or 3 
MAKE/BREAK codes are sent.  Two 
options are available: unsolicited mode 
where codes are sent whenever the 
keyswitch is rotated, or solicited mode 
where codes are sent only when a OP 
Code B7 command is received.  
COMMAND: 
B6<CR> 
 
B6 
= Op Code 
A = unsolicited 
 
B = solicited 
<CR> 
= terminate command (0D hex)   
 