Ultimate Technology 600 POS Manuel D’Utilisation

Page de 81
  
 
Series 600 POS Keyboard 
 
 
 
 
48
  
 
 
Table 5.  Remote Programming Mode Commands 
OP CODE 
(HEX) 
MNEMONIC/DESCRIPTION 
COMMAND/ACKNOWLEDGEMENT 
B1 
BEEPON 
 
Controls pitch and duration of beep.  If 
valued for pitch (p) and duration (d) omitted 
when command activated.  
COMMAND: 
B1pd<CR> 
 
B1 
= Op Code 
= pitch in Hz 
= duration in milliseconds 
<CR> 
= terminate command (0D hex)   
 
pitch (Hz) in ASCII 
 
0 =  500 
 
5 =  880  
 
1 = 2000 
 
6 = 1320  
 
2 =  220  
 
7 = 1760 
 
3 =  440 
 
8 = 2640 
 
4 =  660 
 
9 = 3520 
duration (mS) in ASCII 
 
0 = 1000  
 
5 = 500  
 
1 =  100  
 
6 = 600  
 
2 =  200  
 
7 = 700 
 
3 =  300 
 
8 = 800 
 
4 =  400 
 
9 = 900 
 
ACKNOWLEDGEMENT: NONE 
B2 
SENDP 
 
Sends data to selected port: main serial 
port, auxiliary serial port, or auxiliary 
keyboard port. 
COMMAND: 
B2p...........<CR> 
 
B2 
= Op Code 
= data destination port 
<CR> 
= terminate command (0D hex)   
 
p: 
 
0 = serial port 0 (main) 
 
1 = serial port 1 (auxiliary) 
 
2 = keyboard port 0 (main) 
 
3 = keyboard port 1 (auxiliary) 
 
4 = cash drawer 1 fire  
 
5 = cash drawer 2 fire 
 
Where data can be ASCII or CxDx (high and low 
nibble hex value) type. 
 
ACKNOWLEDGEMENT: NONE