Avital 4103 Manuel D’Utilisation

Page de 52
36
© 2008 Directed Electronics. All rights reserved.
Feature descriptions
The features of the system are described below with default settings in 
bold.
 Menu 1
1 HORN HONK PULSES—ON, 
OFF
:
Turns On/Off the confirmation honks when locking/unlocking. Use it to 
change the output pulse duration for vehicles that require a longer pulse 
for the horn to honk. Confirmation honks ON (20mS) & panic, (1) Con-
firmation honk (30mS) & panic, (2) Confirmation honk (40mS) & panic, 
(3) Confirmation honk (50mS) & panic, (4) Confirmation honk OFF. 
2 IGNITION CONTROLLED LOCK—
OFF
, ON: 
When programmed ON the doors will lock when the key is on and all 
doors are closed.
3 IGNITION CONTROLLED UNLOCK—
OFF
, ON: 
When programme d ON the doors will unlock automatically when the 
key is turned off.
4 DOOR LOCK PULSE DURATlON—
0.8
, 3.5, 0.4 SECONDS: 
Some European vehicles, such as Mercedes-Benz and Audi, require 
longer lock and unlock pulses to operate the vacuum pump. Program-
ming the system to provide 3.5 second pulses, will accommodate the 
door lock interface in these vehicles. The default setting is 0.8 second 
door lock pulses. Some modification to the door lock harness (H2) is 
also necessary. (Refer to TechTip 1041 for wiring information regard-
ing (+/-) Door Lock Outputs Harness (H4)section, Type E - Mercedes-
Benz and Audi -1985 and Newer” diagram.) The 0.4 second pulse is 
required on some of the newer Chrysler and Ford vehicles.