Avital 4103 Manuel D’Utilisation

Page de 52
37
© 2008 Directed Electronics. All rights reserved.
5 UNLOCK OUTPUT—
1
, 2 PULSES: 
This will program the unlock output to one or two pulses. When the dou-
ble pulse unlock feature is turned on, the BLUE (3) wire will supply two 
negative  pulses  instead  of  a  single  pulse.  This  makes  it  possible  to 
directly interface with double pulse vehicles without any extra parts.
6 LOCK OUTPUT—
1
, 2 PULSES: 
This will program the lock output to one or two pulses. The GREEN (1) 
wire  will  supply  two  negative  pulses  instead  of  a  single  pulse.  This 
makes it possible to directly interface with double pulse vehicles without 
any extra parts.
7 FACTORY ALARM DISARM—
WITH UNLOCK
, BEFORE UNLOCK, 
REMOTE START ONLY: 
In the default setting the factory alarm disarm output will disarm the factory 
alarm system any time the button(s) controlling Unlock is pressed. The “Be-
fore Unlock” output to disarms the factory alarm before the unlock output 
activates and before remote start is activated. The “Remote Start Only” 
output disarms the factory alarm only before the remote start is activated.
8 FACTORY ALARM DISARM PULSES—
1
, 2 PULSES: 
Selectable for a single or double-pulse for the vehicle’s factory alarm dis-
arm input requirements.
9 COMFORT CLOSURE—
OFF (1)
The system can be programmed to close the windows when the system is 
locked. If programmed ON, the lock output provides a 20 second pulse 
when the system is locked. The output will be cancelled if the unlock but-
ton is pressed. In the Off setting the system will not do this function.
(2) Comfort closure 1 - Activates the 20 second timer after the door lock 
pulse. (3) Comfort Closure 2 - Activates the 20 second timer with the door 
lock pulse.