Stop Recording 
by Trigger OFF
Detection
(Level Signal Setting)
REC Continue Time 
(Timer Setting)
Stop Recording Priority
Yes
Yes (Level H or Level L)
No
(“Continue”)
1) “STOP” button is pressed.
2) Trigger OFF
Yes
(“1 – 90”)
1) “STOP” button is pressed.
2) Trigger OFF
3) “REC Continue Time”
No
No (H, L, No, or B)
No (“Continue”)
“STOP” button is pressed.
Yes (“1 – 90”)
1) “STOP” button is pressed.
2) “REC Continue Time”
Select either of “H Level (HL)”, 
“L Level (LL)” for Detection 
to stop recording by Trigger OFF
1. Go to “CONFIG”-
”Rec Continue Time
2. Select either of 
“Continue” or “1-90”
(7) Trigger Set up - Stop recording by Trigger OFF
ex. Level H
STOP
REC
STOP
[Remark] 1. If setting up more than 2 triggers as Level Signal, start recording when the 1
st 
trigger is turned on and 
stop recording when all triggers set up as Level Signal are turned off.
2. Minimum recording time is 1 minute when setting up the trigger as Level Signal.
REC Continue 
Timer Setting
Trigger 
Setting
Go to “CONFIG”-”Triggers”