7014-082D
September 1, 2008
CB 1200 Pellet Stove 
Do not terminate vent in any enclosed or semi-enclosed 
area such as a carport, garage, attic, crawl space, under a 
sun deck or porch, narrow walkway or closely fenced area, 
or any location that can build up a concentration of fumes 
such as a stairwell, covered breezeway, etc.
CAUTION
Vent surfaces get HOT, can cause burns if 
touched.  Noncombustible shielding or guards 
may be required.
WARNING
A.  Chimney and Exhaust Connection
1. 
Chimney & Connector:  Use 3 or 4 inch (76-102mm)  
diameter type "L" or "PL" venting system.  It can be 
vented vertically or horizontally.
2. Mobile Home: Approved for all Listed pellet vent.  If 
using the 3 inch (76mm) vertical top vent adapter Kit 
or the 3 to 6 inch (76-152mm)  top vent offset adapter, 
use Listed double wall flue connector.  A Quadra-Fire 
outside air kit must be used with manufactured home 
installations.
3. Residential:  The 3 inch (76mm) vertical top vent 
adapter kit and the 3 to 6 inch (76-152mm) top vent 
offset adapter are tested to use 24 gauge single wall flue 
connector or Listed double wall flue connector to Class 
A Listed metal chimneys, or masonry chimneys meeting 
national and/or local codes for solid fuel appliances.
4.  INSTALL VENT AT CLEARANCES SPECIFIED BY THE 
VENT MANUFACTURER.
5.  Secure exhaust venting system to the appliance with at 
least 3 screws.  Also secure all connector pipe joints with 
at least 3 screws through each joint.
NOTE: All pipe must be welded seam pipe whenever 
possible.  Seal pipe joints with high temperature silicone 
(500°F [260°C] minimum rated only).
NOTE:  If burning shelled field corn, you must use 
approved venting specifically designed for corn.  Follow 
the instructions from the venting manufacturer.
Fire Hazard.
•  Only LISTED venting components may be 
used.
•  NO OTHER vent components may be used.
Substitute or damaged vent components may 
impair safe operation.
WARNING
B.  Venting Termination Requirements
1
.  Termination must exhaust above air inlet elevation.  It is 
recommended that at least 60 inches (1524mm) of verti-
cal pipe be installed when appliance is vented directly 
through a wall.  This will create a natural draft, which 
will help prevent the possibility of smoke or odor venting 
into the home during a power outage.  It will also keep 
exhaust from causing a nuisance or hazard by exposing 
people or shrubs to high temperatures.  The safest and 
preferred venting method is to extend the vent vertically 
through the roof.
2.  Distance from doors and opening windows, or gravity or 
ventilation air inlets into building:
a.  Not less than 48 inches (1219mm) below;
b.  Not less than 48 inches (1219mm) horizontally 
from;
c.  Not less than 12 inches (305mm) above.
3.  Distance from permanently closed windows:
a.  Not less than 12 inches (305mm) below, horizontally 
from or above.
4.  Distance between  bottom of termination and grade 
should be 12 inches (305mm) minimum.  This is con-
ditional upon plants in the area, and nature of grade 
surface.  The grade surface must be a non-combustible 
material (i.e., rock, dirt).  The grade surface must not be 
lawn.  Distance between bottom of termination and public 
walkway should be 84 inches (2134mm) minimum.
5.  Distance to combustible  materials must be 24 inches 
(610mm) minimum.  This includes adjacent buildings, 
fences, protruding parts of the structure, roof overhang, 
plants and shrubs, etc.
6.  Termination Cap Location (Home Electrical Service)
•  Side-to-side clearance is to be the same as minimum 
clearance to vinyl inside corners.
•  Clearance of a termination cap below electrical service 
shall be the same as minimum clearance to vinyl soffits.
•  Clearance of a termination cap above electrical service 
will be 12 inches (305mm) minimum.
•  Location of the vent termination must not obstruct or 
interfere with access to the electrical service.
4
Vent Information