Quadra-Fire CB1200-B Manuel De Montage

Page de 48
September 1, 2008
7014-082D
Page  9
CB 1200 Pellet Stove 
*L Exception for Horizontal Installations:
USA INSTALLATIONS: A non-combustible floor protec-
tion is recommended extending beneath the flue pipe 
when installed with horizontal venting or under the top 
vent adapter with vertical installation.
CANADA INSTALLATIONS:  A non-combustible floor 
protection extending beneath the flue pipe is required 
with horizontal venting or under the top vent adapter with 
vertical installation.
Must extend 2 inches (51mm) beyond each
side of pipe  (shaded area)
C. Hearth Pad Requirements (UL and ULC)
L*
K
K
M
Use a non-combustible floor protector, extending beneath 
appliance and to the front, sides and rear as indicated.  
Measure front distance “M” from the surface of the glass 
door.
Hearth Pad Requirements
Inches
Millimeters
K
Sides
2
51
L*
Back
2
51
M
Front
6
152
Figure 9.1
Figure 9.2