Regency IG35 Gas Inbuilt Fireplace
INSTALLATION
GAS CONNECTION 
3)  Locate the center point where the fl ue will 
pass through the chimney above the appli-
ance.  Move the appliance into the exact 
location where it is to be installed.  Ensure 
that the Insert is level.
CAUTION: If the glass is removed for servic-
ing, it must be replaced and closed prior to 
operating the appliance. 
GAS CONNECTION WARNING:
Only persons licensed to work 
with gas piping may make the 
necessary gas connections to this 
appliance.  
1)  If the appliance is to be installed into an 
existing chimney system or Zero Clearance 
Box, thoroughly clean the masonry or factory 
built fi replace.
2)  The gas connection is 1/2" BSP.
Mantel Clearances 
MINIMUM FIREPLACE 
DIMENSIONS
The minimum fi replace dimensions for the 
Regency gas space heater are shown in the 
following diagrams:
Note:  A non-combustible mantel may be 
installed at a lower height if the fram-
ing is made of metal studs covered 
with a non-combustible board.
MINIMUM 
CLEARANCES TO 
COMBUSTIBLES
The minimum fi replace clearances for the 
Regency gas space heater are shown in the 
following diagrams:
From Unit: 
           
Sides 
 
A 250 mm
Ceiling   
B 1220 mm
Mantel   
C  see Mantel
  
 
Clearances 
From Surround (660 mm x 1016 mm):
Sides
 
 
D 96 mm
Ceiling   
E 1066 mm
Max. Mantle Depth 
G  305 mm
Hearth Height 
H 0 mm
Hearth Depth 
I 300 
mm*
Hearth Width 
J 1100 
mm
Min. Alcove Width 
K 1262 mm
Max. Alcove Depth 
L 915 mm
* NOTE: No hearth required with screen. Floor 
fi nishing material must not be any higher then 
the base of the fi replace.
Premium Flush Front Framing
When installing the Premium Flush Front, the 
walls surrounding the zero clearance kit must 
be made of non-combustible material. See 
Diagram below.