Metrologic Instruments MS9590 Manuel D’Utilisation

Page de 47
 
 
11
Figure 9.
S
CANNER 
I
NSTALLATION
 
 
USB (-106,-38-EAS, and -40-EAS)
‹
  
 
1.  Turn off the host system. 
 
2.  Plug the 10-pin RJ45 end of the 
USB cable into the 10-pin socket 
on the scanner.  There will be an 
audible click when the connector 
lock engages. 
 
3.  Plug the USB Type A end of the 
cable into the host's USB port. 
 
 
Cables supplied with MS9590-
38-EAS and MS9590-40-EAS 
models have additional wires 
for Checkpoint device 
connections.  Refer to page 12 
for additional information on 
Checkpoint device connection. 
 
4.  Turn on the host device. 
 
USB is the default communication protocol for the MS9590-106 and the  
MS9591-106.  Both the -38 interface and the -106 interface scanners have USB 
Keyboard Emulation Mode
 enabled by default when shipped from the factory.  
 
Both the -38 interface and the -106 interface scanners are configurable for  
Bi-Directional Serial Emulation mode.  IBM OEM support is only available with 
the MS9590-106 and the MS9591-106
 
Refer to the USB section in the MetroSelect Single-Line Configuration Guide 
(
MLPN
 00-02544) for USB configuration bar codes. 
 
The scanner is shipped from the factory configured to set of default conditions.  
Plugging the scanner into a port on the host system does not guarantee that the 
scanned information will be communicated properly to the host device.  The 
scanner and host device must use the same communication protocol.  Please 
refer to the MetroSelect Single-Line Configuration Guide or the help files 
provided with MetroSet2 for instructions on changing the scanner’s factory 
default configuration.   
 
See caution on page 6. 
 
‹
  The MS9590-38-EAS and the MS9590-106 meet the requirements for Full Speed USB 
hardware.  These interfaces also support all emulation types previously supported by 
Metrologic in Low Speed USB scanners.