Metrologic Instruments MS9590 Manuel D’Utilisation

Page de 47
 
 
12 
S
CANNER 
I
NSTALLATION
 
 
Additional Settings for EAS Equipped Models 
 
All MS9590 models equipped with EAS capabilities have an EAS designation in 
their model numbers (example: MS9590-38-EAS).  The cable supplied with these 
units will have additional wires for Checkpoint Device connections. 
 
 
Figure 10.  EAS Cable Samples 
 
SW1 and SW2 are the switch banks inside the Checkpoint Device that set the 
deactivation range.  The following is a list of Checkpoint recommended switch 
bank settings. 
 
Checkpoint Recommended Switch Bank Settings 
SW1  
SW2 
Switches 1, 4, 5, and 6 
ON 
Switches 1, 4, 5, and 6  
ON 
Switches 2 and 3 
OFF 
Switches 2 and 3 
OFF 
 
 
 
Figure 11 shows the location of the 
EAS deactivation area.  
 
It is important to pass the entire tag 
through this area to deactivate the 
security tag. 
 
 
 
 
Figure 11.  EAS Deactivation Area