5 – Diagnostics/Troubleshooting
POST Diagnostics
5-4
59042-01 A
c.
Activate binary mode and copy the configuration file from the
workstation to the switch. The configuration file must be named
"configdata".
workstation to the switch. The configuration file must be named
"configdata".
ftp>bin
ftp>put configdata
d.
Close the FTP session.
ftp>quit
e.
Establish communications with the switch using Telnet. Enter one of
the following on the command line:
the following on the command line:
telnet xxx.xxx.xxx.xxx
or
telnet switchname
where xxx.xxx.xxx.xxx is the switch IP address and switchname is the
switch name associated with the IP address.
switch name associated with the IP address.
f.
A Telnet window opens prompting you for a login. Enter an account
name and password. The default account name and password are
(admin, password).
name and password. The default account name and password are
(admin, password).
g.
Open an admin session to acquire the necessary authority.
cli $>admin start
h.
Restore the configuration file.
cli (admin) $>config restore
i.
Reset the switch and close the Telnet session.
cli (admin) $>reset