Q-Logic 8C Manuel D’Utilisation

Page de 162
5 – Diagnostics/Troubleshooting
POST Diagnostics
5-6
59042-01 A
A Logged-In LED error indication is often the result of E_Port isolation. An isolated 
E_Port is indicated by a red link in the topology display. 
 describes the 
causes and remedies for E_Port isolation conditions. Refer to the SANbox2-8c/16 
Switch Management User’s Guide
 for information about how to change domain 
IDs, timeout values, and edit zoning.
If a Logged-In LED is flashing, do the following:
1.
Inspect the cable connecting the port to another switch or to a device. Is the 
cable connected and in good operating condition?
Yes - Continue.
No - Make necessary corrections or replace the cable.
2.
Inspect the switch or device to which the port is connected. Is the switch or 
device operating properly?
Yes - Continue.
No - Make necessary corrections. If the problem remains, continue.
3.
Replace the SFP. Does this correct the problem?
Yes - Diagnosis complete.
No - Continue.
4.
Inspect the switches in the fabric for domain ID, timeout value, or conflicting 
zone name problems. Do any of these conditions exist?
Yes - Reconfigure the switches as needed to eliminate the problem. 
Refer to the SANbox2-8c/16 Switch Management User’s Guide for 
information about how to change domain IDs, timeout values, and 
zoning.
No - Contact your authorized maintenance provider.
Table 5-1. E_Port Isolation Causes and Remedies
Isolation Cause
Remedy
Two switches in the same 
fabric have the same 
domain ID
Correct the domain IDs on the offending switches. 
Domain IDs must be unique.
All switches in the fabric do 
no have the same timeout 
values
Correct the timeout values on the offending switches.
When merging two fabrics, 
the active zone sets contain 
zones with the same names 
but different membership.
Deactivate one of the active zone sets or edit the 
conflicting zones so that their membership is the same. 
The conflicting zones have the same name, but different 
membership. Finally, take the affected ports offline then 
back online to restore the inter-switch links.