Q-Logic MKII-BASE16 Manuel D’Utilisation

Page de 138
4-10
Diagnostics/Troubleshooting
GigWorks MkII-16 Switch Model MKII-BASE16
59003-01 Rev. A             Installer's/User's Manual 
Power-On-Self-Test (POST)
Switch Auto-Route Test Failure (10 Blinks) 
The Switch is operable. The Switch Auto-Route Test verifies the auto-route
capability of individual ports to automatically route frames to the other ports in
the chassis. A failure indicates an inability to successfully route frames between a
port pair and blinks the Heartbeat LED ten times between three-second pauses.
The Switch disables the failing ports or port-pairs and blinks their Logged-in
LEDs.
The ports whose Logged-in LEDs are not blinking have passed the test and are all
useable.
Switch Class 1 Connection Test  Failure (11 Blinks)
The Switch is operable. The Switch Class 1 Connection Test verifies the ability
to perform software controlled Class 1 connections between port-pairs, to pass
frames through the connections, and to perform software controlled disconnects.
A failure indicates an inability to perform a Class 1 connection between a port
pair and blinks the Heartbeat LED eleven times between three-second pauses.
The Switch disables the failing ports or port-pairs and blinks their Logged-in
LEDs.
The ports whose Logged-in LEDs are not blinking have passed the test and are all
useable.
Switch Auto Connect Test Failure (12 Blinks)
The Switch is operable. The Switch Auto Connection test verifies the ability to
perform automatic (or hardware controlled) Class 1 connections between ports, to
pass frames through the connection, and to perform an automatic disconnect
between the port pair. A failure indicates an inability to perform an automatic
Class 1 connection between a port pair and blinks the Heartbeat LED 12 times
between three-second pauses. The Switch disables the failing ports or port-pairs
and blinks their Logged-in LEDs.
The ports whose Logged-in LEDs are not blinking have passed the test and are all
useable.
Arbitrated Loop Test  Failure (13 Blinks)
The Switch is operable. The Arbitrated Loop test verifies the ability of the
Arbitrated Loop ports to initialize properly. A failure indicates the inability to
successfully initialize an Arbitrated Loop (FL) port and blinks the heartbeat LED
13 times between three-second pauses. The Switch disables the failing ports and
blinks their Logged-in LEDs.
The ports whose Logged-in LEDs are not blinking have passed the test and are all
useable.