Q-Logic MKII-BASE16 Manuel D’Utilisation

Page de 138
4-12
Diagnostics/Troubleshooting
GigWorks MkII-16 Switch Model MKII-BASE16
59003-01 Rev. A             Installer's/User's Manual 
Continuous Test
Overview
The Continuous Test button (when set to the TST position) causes the Switch to
go from normal operate mode to continuous test mode. Refer to Figure 3-2.
Figure 4-2  Continuous Test Button
These tests are the same as the POST except the Continuous Test runs more tests.
Among the extra tests, it also runs a loopback test on each GBIC. Therefore, the
Continuous Tests expect that there is a loopback plug installed on each GBIC.
Any GBIC without a loopback plug will fail the GBIC portion of the tests. Refer
to the description of the POST tests earlier in this section.
These tests use the Heartbeat LED to indicate pass or fail conditions on each test.
While the Continuous Test button is in the TST (Out) position, firmware in the
Switch executes the tests continuously but holds the indication for the first failure
encountered and blinks the error’s heartbeat error code. It takes less than one
second for the Switch firmware to run through the tests once.
When you press the Continuous Test button again, setting it to the OP (In)
position, the Switch goes back to normal operate mode and continues to blink the
heartbeat error code which describes the first error encountered (if any). These
error codes were described earlier in this section. As the Switch goes from
continuous test mode to normal operateing mode it reads its error log and if it has
encountered non-fatal errors that effect one or more ports (but the remaining ports
are operable) it will disable the bad ports and blink the Logged-in LED of the
affected port or ports to indicate which ports are down. If the error is non-fatal
and does not affect an individual port or ports, only the Heartbeat LED blinks an
error code. The Switch displays the error indications until you reset it or power it
down.
Continuous Test button
(Must be OFF (IN) for 
normal operation)
TST
OP
2
4
6
8
10 12
14 16
1
3
5
7
9
11
13 15
TST
OP
COMMUNICATIONS, INC.
WORKS™
Rx
Tx
Rx
Tx
Rx
Tx
Rx
Tx
Rx
Tx
Rx
Tx
Rx
Tx
Rx
Tx
Rx
Tx
Rx
Tx
Rx
Tx
Rx
Tx
Rx
Tx
Rx
Tx
Rx
Tx
Rx
Tx
MKII
Continuous Test