Emerson MODBUS 485 Manuel D’Utilisation

Page de 372
Modbus 485 and Modbus IP Protocols - Thermal Management Products
Liebert
®
 IntelliSlot
®
 Modbus/BACnet IP
8
Compressor Pump Down Issue 2
10044
 —
1
Active on Alarm
1, 2, 3, 4, 5, 6
Dig Scroll Comp Over Temp 1
10045
 —
1
Active on Alarm
1, 2, 3, 4, 5, 6
Dig Scroll Comp Over Temp 2
10046
 —
1
Active on Alarm
1, 2, 3, 4, 5, 6
Smoke Detected
10047
 —
1
Active on Alarm
1, 2, 3, 4, 5, 6
Water Under Floor
10048
 —
1
Active on Alarm
1, 2, 3, 4, 5, 6
Humidifier Issue
10049
 —
1
Active on Alarm
1, 2, 3, 4, 5, 6
Ext Standby Glycol Pump On
10050
 —
1
Active on Alarm
1, 2, 3, 4, 5, 6
Ext Standby Unit On
10051
 —
1
Active on Alarm
1, 2, 3, 4, 5, 6
Ext Condenser Pump High Water
10052
 —
1
Active on Alarm
1, 2, 3, 4, 5, 6
Return Air Sensor Issue
10053
 —
1
Active on Alarm
1, 2, 3, 4, 5, 6
Ext Loss of Air Blower
10055
 —
1
Active on Alarm
1, 2, 3, 4, 5, 6
Humidifier Low Water
10058
 —
1
Active on Alarm
1, 2, 3, 4, 5, 6
Humidifier Over Current
10059
 —
1
Active on Alarm
1, 2, 3, 4, 5, 6
Ext Over Temperature
10060
 —
1
Active on Alarm
1, 2, 3, 4, 5, 6
Shutdown - Loss Of Power
10061
 —
1
Active on Alarm
1, 2, 3, 4, 5, 6
Supply Chilled Water Over Temp
10065
 —
1
Active on Alarm
1, 2, 3, 4, 5, 6
Return Air Over Temperature
10067
 —
1
Active on Alarm
1, 2, 3, 4, 5, 6
Return Air Under Temperature
10068
 —
1
Active on Alarm
1, 2, 3, 4, 5, 6
High Return Humidity
10069
 —
1
Active on Alarm
1, 2, 3, 4, 5, 6
Low Return Humidity
10070
 —
1
Active on Alarm
1, 2, 3, 4, 5, 6
Ext Air Sensor A Over Temperature
10071
 —
1
Active on Alarm
1, 2, 3, 4, 5, 6
Ext Air Sensor A Under Temperature
10072
 —
1
Active on Alarm
1, 2, 3, 4, 5, 6
Ext Air Sensor A High Humidity
10073
 —
1
Active on Alarm
1, 2, 3, 4, 5, 6
Ext Air Sensor A Low Humidity
10074
 —
1
Active on Alarm
1, 2, 3, 4, 5, 6
Supply Chilled Water Loss of Flow
10075
 —
1
Active on Alarm
1, 2, 3, 4, 5, 6
Clogged Air Filter
10076
 —
1
Active on Alarm
1, 2, 3, 4, 5, 6
Supply Air Sensor Issue
10077
 —
1
Active on Alarm
1, 2, 3, 4, 5, 6
Free Cooling Temp Sensor Issue
10078
 —
1
Active on Alarm
1, 2, 3, 4, 5, 6
Ext Air Sensor A Issue
10079
 —
1
Active on Alarm
1, 2, 3, 4, 5, 6
Fan Hours Exceeded
10080
 —
1
Active on Alarm
1, 2, 3, 4, 5, 6
Compressor Hours Exceeded 1
10081
 —
1
Active on Alarm
1, 2, 3, 4, 5, 6
Compressor Hours Exceeded 2
10082
 —
1
Active on Alarm
1, 2, 3, 4, 5, 6
Free Cooling Valve Hours Exceeded
10083
 —
1
Active on Alarm
1, 2, 3, 4, 5, 6
Electric Reheater Hours Exceeded 1
10084
 —
1
Active on Alarm
1, 2, 3, 4, 5, 6
Table 6
Liebert Challenger 3000
, Liebert Challenger ITR
, Liebert CW
, Liebert Deluxe System/3
Liebert DS
, Liebert DSE
, Liebert HPM
, Liebert PeX
 - Status and Coil (continued)
Controller
Liebert iCOM
®
 v4
Liebert Products
Units with 
Liebert iCOM
®
:
Liebert HPM
Units with Liebert iCOM Firmware
PA1.04.033.STD or later:
Liebert Challenger 3000
Liebert Challenger ITR
Liebert CW
Liebert Deluxe System/3
Liebert DS
Liebert DSE
Liebert PeX
Available Points
Data Label
Status
Coil
Number
of Bits
Notes / Units
Extra Notes